Duct Style heat exchange system HESOX

Jet + mixed airflow organization according to aerodynamics.

According to the characteristics of fresh air sent by livestock houses in winter, Liangmo and China Agricultural University(Animal Science and Technology College - Livestock Engineering Research Office) jointly developed designed to solve the cattle, pig, chicken house problem of environmental protection and energy saving in the winter.

Unique heat exchange flow path design, heat exchange efficiency is over 70%,use the waste gas energy and fresh air energy exchange.The air supply duct adopts a fiber duct tapered design, and the air supply is more balanced.The airflow organization in the house is more reasonable,exhaust harmful gases such as carbon dioxide and ammonia.

1.can be custom a hot exchange system for raising pigs,cattles, chickens


2. the schematic diagram is as follows:



The core component of the HESOX system is a full heat exchange chamber. The dirty air discharged from the house and the fresh air sent in the room exchange temperature through the heat transfer pipe, thereby achieving the effect of both ventilation and indoor temperature stability.



3. what can bring to the customers:


Heat exchange energy-saving input-output ratio


Taking Hebei and Shandong as examples

Each pig house is fed with 1,000 fattening pigs. The fresh air volume is 17000m^3/h, the outside temperature is -10C°, and the required temperature is 18C°. To warm the outside air to the required temperature of 18C°.Need electric heating, need energy consumption 170KW/h

4. the product is special.






>